HY-LXP21E Illuminance Monitor
Details
Brief Introduction
The HY-LXP21E measures the level of illuminance within the tunnel bore to ensure interior illumination levels are being continuously maintained in order to affect safe lighting conditions for drivers. Illuminance, or incident lighting, determines the amount of light that covers a specific surface or area within the tunnel.
Designed specifically for the tunnel environment, the HY-LXP21E continuously measures cosine corrected planar illuminance within the tunnel thus allowing elimination of directional error. The HY-LXP21E measures the illuminance over a standard range of 0 - 20,000 lux.Features
- CIE Approved measurement technology
- Accurate measurement of illuminance within tunnel
- Designed specifically for tunnels
- Rugged construction
- Simple installation/operation
- Isolated 4-20mA analogue outputs
- Alarm relay contacts
- ModBus serial output
Technical Specification
Detector |
Silicon photo diode |
Measurement Range |
0-2000 lx |
Resolution |
1 lx |
Accuracy |
±1% |
Voltage |
100-240VAC |
Power Consumption |
36 Watt |
Output |
RS485(MODBUS) |
4-20mA(Isolated) |
|
two way relay 2A@24VDC |
|
IP Grade |
IP66 |
Operating Temperature |
-30~70℃ |
Operating Humidity |
0-100% |
Materials |
Powder coated steel |
Dimensions |
376x136x164 mm L x W x H |
Weight (each) |
3 Kg |
Warranty |
24 Months |
Site Photos
Contact : | Stefan |
---|---|
Phone : | +86 18681878709 |
Email : | stefan@hongyuv.com |
QQ : | 2146432059 |
Skype : | stefan@hongyuv.com |
Wechat : | wswgenius |
Address : | Room 7th,Floor 3rd ,Block 1st, Xinye Road 4th,Gaoxin Zone,Pidu Zone,Chengdu City,Sichuan Province,China |